Synthes distal fibula inventory.

The 2.0 mm LCP Distal Ulna Plate is indicated for fixation of fractures, osteotomies, nonunions, replantations, and fusions of small bones and small bone fragments, particularly in osteopenic bone. 4 DePuy Synthes 2.0 mm LCP® Distal Ulna Plate Surgical T. Clinical Examples Examples include: - Fractures of the ulnar head where the articular ...

Synthes distal fibula inventory. Things To Know About Synthes distal fibula inventory.

Consult Depuy Synthes's entire VA LCP ® Distal Radius System catalogue on MedicalExpo. Page: 1/8The distal radius and distal ulna form a three-column biome-chanical construction 3: – The ulnar column is the distal ulna, the triangular fibrocar-tilage and the distal radio-ulnar joint. – The intermediate column is the medial part of the distal radius, with the lunate fossa and the sigmoid notch.Jun 3, 2013 · Fig 7 VA-LCP Lateral Distal Fibula Plate with six 2.7 mm VA holes in the head in Stainless Steel VA-LCP Lateral Distal Fibula Plate in Titanium The Variable Angle LCP Ankle Trauma system also comprises a compression and distraction system, which is an important tool for reduction (i.e. bringing a fibula out to length) or compression of a ...Consult Depuy Synthes's entire VA LCP ® Distal Radius System catalogue on MedicalExpo. Page: 1/8The LCP posterolateral distal fibula plate offers six round locking holes and two coaxial holes distally which accept 2.4 and 2.7 mm locking and cortex screws to provide multiple screw options. The distal holes are slightly divergent to help prevent screw pullout. The coaxial hole accepts both locking and cortex screws and its recess for screw ...

The 2.7/3.5 mm LCP lateral distal fibula is an anatomically designed plate for the treatment of fractures, osteotomies, and nonunions of the metaphyseal and diaphyseal region of the distal fibula, especially in osteopenic bone. The plate has an anatomically precontoured head and a low-profile design. It comes in right and left versions with lengths from 3 …The Large External Fixation System uses a modular construction to allow flexibility and a variety of forms of assembly to externally stabilize long bones, pelvic ring fractures, arthrodesis, and osteotomies. The system combines the Modular Knee Bridge and the Pelvic Frame. Product Specifications.

Quick steps to complete and e-sign Va ankle inventory online: Use Get Form or simply click on the template preview to open it in the editor. Start completing the fillable fields and carefully type in required information. Use the Cross or Check marks in the top toolbar to select your answers in the list boxes.

Locking Distal Fibula Plates, Right QTY PRODUCT # HOLES PRICE LOT# UDI AR-9943BR-04 4 AR-9943BR-05 5 AR-9943BR-06 6 AR-9943BR-08 8 AR-9943BR-10 10 AR-9943BR-12 12 AR-9943BR-14 14. Page 2 of 9 oe a oa ege a oea foao ao oee ea foao P ee oe fo e e of e ee ae aoe f o ae o e ee o e eoee o ageVariable Angle Locking Screw Technology. Variable angle (VA) locking screw technology allows freedom to choose screw trajectory up to 15° in each direction to avoid existing implants, prosthesis, or independent lag screws. A variety of lengths are available which allow for desired spanning of the femur. 4.Locking Distal Fibula Plates, Right QTY PRODUCT # HOLES PRICE LOT# UDI AR-9943BR-04 4 AR-9943BR-05 5 AR-9943BR-06 6 AR-9943BR-08 8 AR-9943BR-10 10 AR-9943BR-12 12 AR-9943BR-14 14 Locking Third Tubular Plates ... Inventory Control Form Author: Arthrex, Inc. Subject:3.5 mm LCP® Medial Distal Tibia Plates The 3.5 mm LCP® Medial Distal Tibia Plate is part of the DePuy Synthes LCP System that merges locking screw technology with conventional plating techniques. The plate is offered in stainless steel and features a limited-contact shaft profile, Combi holes in the shaft, and locking screw holes in the head.The 2.7 mm/3.5 mm LCP® Distal Fibula Plates DePuy Synthes locking compression plate locking screw technology with conventional. The plates are available in stainless steel feature an anatomic shape and profile, both the fibular shaft. The Combi holes in the combine a dynamic compression unit (DCU) locking screw hole.

Wonka showtimes near century huntington beach and xd

Our Trauma & Extremities portfolio offers comprehensive solutions for the treatment of fractures, deformities, and other orthopaedic traumas. Our wide range of surgical instruments and fixation products are designed to provide solutions tailored to the diverse needs of orthopaedic professionals and patients. Get In Touch With a Sales Consultant.

DePuy Synthes, part of the Johnson & Johnson Family of Companies, is a global leader in medical devices used to treat orthopaedic trauma. The company's fixation products, including screws, plates, nails and other implants, are used to treat fractures and deformities related to the extremities and provide one of the most comprehensive portfolios of orthopaedic solutions in the world.LCP Dia-Meta Volar Distal Radius Plates LCP Distal Fibula Plates LCP Distal Humerus Plates LCP Distal Radius System 2.4 LCP Distal Tibia Plate LCP Distal Ulna Plate LCP Extra-articular Distal Humerus Plate LCP Hook Plate 3.5 LCP Locking Compression Plate LCP Low Bend Medial Distal Tibia Plates 3.5 mm LCP Medial Proximal Tibial Plate 3.514 DePuy Synthes LCP Distal Radius System 2.4 Surgical Technique Locking screws X12.806-830 Locking Screw B 2.4 mm, self-tapping X0026-230. 2 we r cSng ockLi B 2.7 mm (head 2.4), gnppia t - lf e s Cortex screws X01.756-780 Cortex Screw B 2.4 mm, self-tapping X02.870-890 Cortex Screw B 2.7 mm, self-tapping ...It is compatible with all DePuy Synthes distal fibula plates and any plate hole that accepts a 4 mm non-locking cortex screw. 7 "The acquisition of Akros and subsequent launch of this key technology demonstrate a clear focus on accelerating meaningful innovation and strengthening DePuy Synthes' Extremities portfolio - providing diverse ...Pediatric LCP® Plate System Surgical Technique DePuy Synthes 5 Pediatric LCP Plates are available in the following sizes and angles.* Pediatric LCPPlates **Screws sold separately **Additionally available. Angle Recommended Use 2.7 mm Plates 3.5 mm and 5.0 mm Plates 90˚ (Condylar) Distal femur osteotomies and fractures 3, 5, or 7 holesLocking Distal Fibula Plates, Right QTY PRODUCT # HOLES PRICE LOT# UDI AR-9943BR-04 4 AR-9943BR-05 5 AR-9943BR-06 6 AR-9943BR-08 8 AR-9943BR-10 10 AR-9943BR-12 12 AR-9943BR-14 14 Locking Third Tubular Plates ... Inventory Control Form Author: Arthrex, Inc. Subject:2) Fibula Link Link has OD of 2.8 mm and is 10.7 mm long; External threads have 40 threads per inch 4) Tibia Screw Screw is 22 mm long, starts with 4.0 mm cortical threadform at proximal end, transitioning to 4.0 mm cancellous threadform at distal end 3) PERMACORD® Suture Bridge 4 mm bridge consists of 4 strands of #1 Ultra High Molecular

The LCP Distal Fibula Plates are part of the Synthes locking compression plate system that merges locking screw technology with conventional plating techniques. The plates …Distal Humerus Plates Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form Titanium 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 04.107.002 2 holes, right 04.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal ...Offset syndesmotic and lateral fibula plates allow for precise syndesmotic fixation. Versatile, low-profile plate designs are Type II anodized, pairing increased strength with minimal construct prominence. System features a wide range of plates including hook, medial & posterior tibia, 1/3 tubular and syndesmosis plates. Contact your sales rep.Fibula plate Make a straight lateral or posterolateral surgical incision to expose the fibular fracture, the distal fibula, and the fibular diaphysis. A lateral incision directly over the …The Variable Angle LCP™ Curved Condylar Plate is a distal femur implant designed to address multiple patient anatomies, fracture patterns and surgical situations including supracondylar, intra-articular and extra-articular condylar fractures, and periprosthetic fractures. Product Specifications. How to Use This Product.SYNTHES (CANADA) LTD. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 Fax: (905) 567-3185 To order: (800) 668-1119 SYNTHES (USA) 1690 Russell Road Paoli, PA 19301-1262 Telephone: (610) 647-9700 Fax: (610) 251-9056 To order: (800) 523-0322 Original Instruments and Implants of the Association

• Distal Fixation 81 Alternative Surgical Technique 83 • Preoperative Planning 83 • Patient Positioning and Approach 84 • Guide Wire Insertion 85 LCP Pediatric Condylar Plate 90°, 3.5 and 5.0 88 • Preoperative Planning 88 • Patient Positioning and Approach 90 • Guide Wire Insertion 91 • Osteotomy 97 • Distal Fixation 99SYNTHES (CANADA) LTD. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 Fax: (905) 567-3185 To order: (800) 668-1119 SYNTHES (USA) 1690 Russell Road Paoli, PA 19301-1262 Telephone: (610) 647-9700 Fax: (610) 251-9056 To order: (800) 523-0322 Original Instruments and Implants of the Association

synthes.vo.llnwd.netThe FRN-ADVANCED System is intended for treatment of fractures in adults and adolescents in which the growth plates have fused. Intended applications include: Subtrochanteric fractures. Ipsilateral neck/shaft fractures. Femoral shaft fractures. Impending pathologic fractures. Malunions and nonunions. Get in Touch with a Sales Consultant.synthes distal fibula inventory. synthes va elbow inventory. Create this form in 5 minutes! Use professional pre-built templates to fill in and sign documents online faster. Get access to thousands of forms. Get form. How to create an eSignature for the synthes non locking small frag inventory.Please contact your sales consultant for items approved for sale in Canada. VALCPDISRADPLATICF001 04/22. Open the catalog to page 1. Inventory Control Form Variable Angle LCP Distal Radius Plates Implants (cont’d) 2.4 mm VA LCP Volar Rim Distal Radius Plates 2.4 mm VA LCP Dorsal Distal Radius Plate, Intermediate Column …6 DePuy Synthes 3.5 mm LCP ® Hook Plate Surgical Technique. Clinical Cases. Case 2* – 61-year-old male – Open distal humerus fracture: right arm – Good bone quality – Olecranon osteotomy required to repair distal humerus. Preoperative lateral Postoperative AP Postoperative lateral Preoperative lateral Postoperative AP Postoperative ...Place your e-signature to the PDF page. Simply click Done to save the changes. Download the papers or print your copy. Distribute immediately to the receiver. Make use of the fast search and innovative cloud editor to produce an accurate Synthes Distal Radius Inventory. Get rid of the routine and create paperwork on the web!Brochure_FINAL. Catalog excerpts. DePuy Synthes Quality. Value. Including Sterile Solutions Procedure constructs designed for the Ambulatory Surgery Center. Open the catalog to page 1. WRIST DePuy Synthes Pro-Pak Distal Radius - VA Construct includes 1 plate, up to 9 screws, and 1 drill bit DePuy Synthes Pro-Pak Distal Radius - VA (Sterile ...The DePuy Synthes 4.5 mm LCP® Condylar Plate is part of the LCP Periarticular Plating System, which merges locking screw technology with conventional plating techniques. The LCP Periarticular Plating System is capable of addressing complex fractures of the distal femur with the 4.5 mm LCP Condylar Plates, complex fractures of the proximal femur

Www naturist freedom com

About This Product. The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treatment of nonunions, malunions, and osteopenic bone. They are available in the following options: 3.5 mm LCP Proximal Tibia Plate. 3.5 mm LCP Proximal Tibia Plate – Low Bend. 4.5 mm LCP Proximal Tibia Plate.

Schanz screw laterally, aiming for the fibular head. 2. Insert distal Schanz screw The distal Schanz screw should be placed 10 mm above and parallel to the tibial plafond. Note: For extreme distal tibia fractures, there is the option of inserting the distal pin through the tuberosity of the calcaneus.Edit Synthes va distal radius inventory. Easily add and highlight text, insert images, checkmarks, and icons, drop new fillable fields, and rearrange or delete pages from your document. Get the Synthes va distal radius inventory accomplished. Download your modified document, export it to the cloud, print it from the editor, or share it with ...Inventory Control Form 3.5/4.5 MM VA LCP™ PERIPROSTHETIC PROXIMAL FEMUR PLATING SYSTEM 3.5 mm VA-Locking PPFx Greater Trochanter Ring Attachment Plates, ... 3.5 mm VA-Locking PPFx Distal Femur Spanning Attachment Plates, LEFT, SSt Holes Length 02.221.151 4 holes 142 mm 02.221.153 4 holes LONG 152 mm 02.221.155S* 6 holes 182 mmPurchase a discounted Synthes 02.112.110 LCP Posterolateral Distal Fibula Plate, Right from Alpha Biomedical with a 6 month warranty. Site Information. MAIN MENU. Home; Sell Your Surgical Instruments; ... Synthes 02.112.143 LCP Lateral Distal Fibula Plate, 6 Hole, Left . $225.00. Add To Cart. Join Our Mailing List for special offers! Name ...Distal Humerus Plates Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Platesslightly distal to the hinged part of the table to allow flexion of the knee during surgery. Avoid too strong a traction and a fully extended knee, as the forces of the gastrocnemius muscle would draw the distal fragment into recurvatum. This does not only make the reduction of the fracture difficult, but also endangers the popliteal artery and ...Schanz screw laterally, aiming for the fibular head. 2. Insert distal Schanz screw The distal Schanz screw should be placed 10 mm above and parallel to the tibial plafond. Note: For extreme distal tibia fractures, there is the option of inserting the distal pin through the tuberosity of the calcaneus.3.5 mm VA LCP® Proximal Tibia Plate, Small Bend Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. 02.127.210 4 holes, 87 mm, right 02.127.211 4 holes, 87 mm, left 02.127.220 6 holes, 117 mm, right 02.127.221 6 holes, 117 mm, left 02.127.230 8 holes, 147 mm, right 02.127.231 8 holes, 147 mm, left 02.127.240 …Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10176-B 3/13 2.4 mm/2.7 mm Titanium VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm Titanium VA-LCP Forefoot/Midfoot Plating System 04.211.230 0° right 04.211.231 0 ...

The Universal Small Fragment (USF) System is intended to be used for small bone trauma, including anatomy such as Shoulder, Clavicle, Elbow, Tibia and Fibula. The core set can support any DePuy Synthes 2.7mm or 3.5mm non-locking, LCP® or VA LCP® Implant System. Training topics for USF. System Trays. Instruments.Nevertheless, in distal fibula fractures, the evidence of MIPO remains scarce. The aim of this retrospective study was to compare the clinical and radiological outcomes of the minimally invasive techniques applied to the distal fibula with open reduction and internal fixation within a 12 months follow-up.The DePuy Synthes 4.5mm VA-LCP Curved Condylar Plate System has been approved by the FDA for "buttressing multi-fragmentary distal femur fractures including: supracondylar, intra-articular and extra-articular condylar fractures, periprosthetic fractures, fractures in normal or osteopenic bone, and non-unions and malunions."3.5 mm VA LCP® Proximal Tibia Plate, Small Bend Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. 02.127.210 4 holes, 87 mm, right 02.127.211 4 holes, 87 mm, left 02.127.220 6 holes, 117 mm, right 02.127.221 6 holes, 117 mm, left 02.127.230 8 holes, 147 mm, right 02.127.231 8 holes, 147 mm, left 02.127.240 …Instagram:https://instagram. sound of freedom showtimes near santikos northwest 14 Arthrex offers a wide variety of solutions in our ankle fracture portfolio, including titanium plating options. Plate offerings include locking third tubular plates, 3.5 mm reconstruction plates, and the locking distal fibular plate. Each plate is designed for use with the Syndesmosis TightRope ® XP implant and includes a compression hole in ... who beat james holshouser on jeopardy slightly distal to the hinged part of the table to allow flexion of the knee during surgery. Avoid too strong a traction and a fully extended knee, as the forces of the gastrocnemius muscle would draw the distal fragment into recurvatum. This does not only make the reduction of the fracture difficult, but also endangers the popliteal artery and ... is martha maccallum leaving fox LCP Distal Femur and LCP Proximal Lateral Tibia (LISS) Stainless Steel and Titanium. Synthes (USA) To Order: (800) 523-0322 Synthes (Canada) Ltd. To Order: (800) 668-1119. amber pitner cartersville ga You're reviewing: Synthes - 02.112.148 - Synthes 2.7mm/3.5mm Lcp Lateral Distal Fibula Plate 9 Hole/Right/151mm Your Rating. Price. 1 star 2 stars 3 stars 4 stars 5 stars. Quality. 1 star 2 stars 3 stars 4 stars 5 stars. Value. 1 star 2 stars 3 stars 4 stars 5 stars. Nickname. Summary. Review. Submit Review. navy seal sidearm The LCP Distal Fibula Plates are part of the Synthes locking compression plate system that merges locking screw technology with conventional plating techniques. The plates … snfclinic login Related to synthes distal fibula plate inventory control form A strong partnership to improve education in India. 16 A strong partnership to improve education in India LGT Venture Philanthropy (LGT VP) has been a staunch in securing external funding post their committed. Fill Now. Gas Built-in Cooking Appliances ... under the oak tree chapter 84 Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4/2.7, Extra-long Variable Angle LCP Volar Rim Distal Radius Plate 2.4 Variable Angle Locking Hand System Please read these instructions for use, the Synthes brochure"Important Informa-tion" carefully before use.Discover the 3.5mm LCP® Clavicle Hook Plate developed by DePuy Synthes for lateral clavicle fractures and acromioclavicular joint injuries.Quickly produce a Synthes Large Frag Inventory without needing to involve specialists. There are already over 3 million users making the most of our unique collection of legal forms. ... humerus, radius, ulna, pelvis, distal tibia, and fibula, particularly in osteopenic bone. What size is a mini frag? The Mini Fragment System (or "Mini Frag ... promo code papa murphy's Plating options that considers all distal radius and distal ulna fracture needs; Titanium dorsal and Stainless steel forearm options; Low-Profile. Plates and screws designed to ensure an overall low-profile construct, whether screws are placed on or off-axis. One locking screw.Product Codes: 02.118.002, 02.118.002S, 02.118.003... View More. PRODUCT CODES. DESCRIPTION. The 2.7 mm/3.5 mm VA LCP™ Ankle Trauma System is a … 2002 polaris edge x 700 Oct 22, 2020 · The FIBULINK ® Syndesmosis Repair System Implants are offered in stainless steel or titanium, and are provided in sterile, single use kits. It is compatible with all DePuy Synthes distal fibula plates and any plate hole that accepts a 4 mm non-locking cortex screw. 7. “The acquisition of Akros and subsequent launch of this key technology ...Additional Info. Unit of Measurement: Each. Catalog Number: 01.112.077. Set includes an assortment of instruments, implants and a storage case. CLICK HERE for list of contents. Examples of plates and instruments (depth gauge) shown below. Trials available. Photo is representative—please contact your sales rep for more complete details. 2016 gmc acadia ac recharge According to the NAHB report for March, builders remained cautiously optimistic in April as limited resale inventory helped to increase demand in the new home market. According to ... portland rose garden arena seating chart 14 Synthes Large and Medium-Size External Fixators Surgical technique Approach to the femur A lateral approach to the femur within a 30° angle is recom-mended. A medial approach is also possible from a distal direc-tion. Approach to the pelvis There are two recommended options for pin placement of the external fixation assembly in the pelvis.The FIBULINK Syndesmosis Repair System Implants are offered in stainless steel or titanium, and are provided in sterile, single use kits. It is compatible with all DePuy Synthes distal fibula plates and any plate hole that accepts a 4 mm non-locking cortex screw.7. "The acquisition of Akros and subsequent launch of this key technology ...